AIRLESSCO SL1500 Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Stříkací barva AIRLESSCO SL1500. AIRLESSCO SL1500 Instruction manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - SERVICE/OPERATION

001-826 FEB09®AIRLESSCO - SL1500AIRLESS PAINT SPRAYERSERVICE/OPERATIONMANUAL

Strany 2 - TABLE OF CONTENTS

89PRESSURE RELIEF PROCEDURE5. Re-engage gun safety latch and close Prime/Pressure Relief Valve.TO AVOID POSSIBLE SERIOUS BODY INJURY, ALWAYS FOLLOW TH

Strany 3 - INTRODUCTION

89SPRAYAttach spray gun to airless unit and tighten ttings securely. Set the gun safety latch. (Also may be called gun safety lock, or trigger lock)

Strany 4 - WARNINGS

1011FIG. 11AIRLESS SPRAY GUN 3*10987542*1*1421171615131211*1819620PARTS LIST FIGURE 11Item No. Part No. Description1 120-530* Gun Seat Assembly2 120-5

Strany 5 - WARNINGS - CONTINUED

1011AIRLESS SPRAY TROUBLESHOOTINGDEFECTS CAUSE CORRECTIONCoarse spray Low pressure Increase the pressureExcessive fogging(overspray)High pressureMate

Strany 6

1213Thickness of the paint coat per stroke is determined by spray tip "fan width", rate of the spray gun movement, and distance to surface.

Strany 7 - HOW TO FLUSH

12 13REGULAR MAINTENANCE1. Always stop the pump at the bottom of its stroke when you take a break or at the end of the day. This helps keep material f

Strany 8 - STARTING UP

1415PROBLEM CAUSE SOLUTIONUnit doesn’t prime Airleak due to: • Loose suction nut • Worn o-ringsStuck or fouled ballsPrime/Pressure Relief valv

Strany 9

14 15SERVICING THE FLUID PUMPFLUID PUMP DISCONNECT FLUID PUMP REINSTALL1. Flush out the material you are spraying, if possible.2. Follow the Pressure

Strany 10 - IMPORTANT!

1617SERVICING THE INLET & OUTLET VALVESFIG. 20FIG. 21SUCTION VALVE1. Gently tap the inlet valve nut counter clockwise and remove.2. Remove the in

Strany 11 - AIRLESS SPRAY GUN OPERATION

161711. Take the upper female gland & place on top of your assembled upper packings with the inverted side down.12. Take your assembled upper gla

Strany 12 - AIRLESS SPRAY GUN

21TABLE OF CONTENTSSECTION FIGUREIntroduction... 1Safety Warnings ...

Strany 13 - TEST THE PATTERN

181929561871012131123282422212026251917161518143412723SL1500 PUMP PARTS DIAGRAM 295618 7 10 1213 1117 27 28 24 22 21 20 26 25 1917 16151814341FIG. 22F

Strany 14 - TIP SELECTION GUIDE

1819SL PUMP PARTS LIST (187-411)SL 1500 PUMP REPAIR KITSPart No. Description301-443 Packing Kit *301-444 Major Repair Kit +*187-411 Replacement PumpFI

Strany 15 - ELECTRIC MOTOR MAINTENANCE

20 21PARTS LIST FIGURE 27Item No. Part No. Description1 111-202 Base2 301-356 Spring3 106-007 O-Ring4 111-204 Filter 60 Mesh5 111-203 Support6 111-201

Strany 16 - FIELD TROUBLESHOOTING

2021PARTS LIST FIGURE 28Item No. Part No. Description1 119-110 Black O-Ring2 189-587 Suction Nut3 100-668 Suction Elbow4 100-664 1” ID Suction HoseFIG

Strany 17 - SERVICING THE FLUID PUMP

2223COMPLETE SPRAYER FIG. 30123456789101113141617181917202122242325262729303132333536,37,38,41494250515253542843443445464748SEE FIGURE 2327

Strany 18 - PARTS LIST FIGURE 20 & 21

2223COMPLETE SPRAYER PARTS LISTPARTS LIST FIGURE 30Item No. Part No. Description1 301-320 Cover2 100-312 Screw (4)3 100-360 Screw (2)4 301-105 Hook5 3

Strany 19 - REASSEMBLY

2425Cause StepsControl Settings STEP 1: After making sure that the machine is plugged into the wall, verify that the on-off switch is in the ON positi

Strany 20 - SL1500 PUMP PARTS DIAGRAM

2425PRESSURE CONTOL ASS'Y CALIBRATIONNOTE: ANYTIME A SENSOR OR PRESSURE CONTROL ASSEMBLY (BOARD) OR BOTH ARE REPLACED, THE FOLLOWING CALIBRATIONS

Strany 21 - PRIME VALVE (119-083)

2627PARTS LIST FIGURE 31Item No. Part No. Description1331-168301-101Electrical Cord 110VElectrical Cord 230V2 331-185 Strain Relief3 331-138 Screw4 30

Strany 22 - PAINT SYSTEM

2627123456REPLACEMENT OF ELECTRICAL COMPONENTSWARNING: ALWAYS UNPLUG THE ELECTRICAL CORD BEFORE SERVICING MACHINE!NOTE: ANYTIME THE PRESSURE CONTRO

Strany 23 - PARTS LIST FIGURE 29 CONT

21INTRODUCTIONNO MODIFICATIONS or alterations of any AIRLESSCO Equipment or part is allowed.All Service Procedures to be performed by an Authorized Ai

Strany 24 - COMPLETE SPRAYER

28 29OPTIONAL AIR ATOMIZER (120-117)OPTIONAL HOPPER SYSTEM (301-441)FIG. 34• For best performance use at least a minimum 1 gallon per minute paint

Strany 26

AIRLESSCOACCESSORIESStrong yet flexible, for airless sprayers up to 3300 PSI Part No: Hose Description 100-012 3/16” Whip Hose, 4 Ft. 10

Strany 27 - 4. PASE LIMIT CALIBRATION

23NOTE TO PHYSICIAN: Injection in the skin is a traumatic injury. It is important to treat the injury surgically as soon as possible. DO NOT

Strany 28 - ELECTRICAL SYSTEM

23WARNINGS - CONTINUEDHazardous uid or toxic fumes can cause serious injury or death if splashed in eyes or on skin, inhaled or swallowed. Know the h

Strany 29

45This sprayer operates at 3000 psi (205 bar). ALWAYS be sure that all components and accessories have a maximum working pressure of at least 3000 psi

Strany 30 - OPERATING INSTRUCTIONS

45WARNING: To reduce the risk of static sparking, which can cause re or explosion, always hold a metal part of the gun rmly against the metal pail w

Strany 31

67SETTING UPFIG. 5 1. CONNECT THE HOSE AND GUN 2. FILL THE PACKING NUT/WET CUP 4. GROUNDINGa. Remove the plastic cap plug from the outlet and screw

Strany 32 - ACCESSORIES

672. PREPARE THE MATERIALa. Turn the Pressure Control Knob Clockwise to increase pressure and counterclockwise to decrease pressure.b. Always use th

Komentáře k této Příručce

Žádné komentáře